Pneumatic compressor problem 

A machine shop is using a compressor that has an output of 1300-CFM.  A maximum facility demand of 1500-CFM is needed for 20-seconds.  The initial working pressure is 90-psi.   The circuit pressure cannot drop blow 60-psi.   Please size the receiver that is needed for this application?

V= receiver size in cfm
T = time in sec
Qin = flow rate in
 
Qout = flow rate out
Pa= atmospheric pressure
P1 = initial working pressure
P2 = finial working pressure
Thank you,

Professor P.V.Btfsplk

 

Certification   Membership    Education/Training    Contact Us 

The Fluid Power Society
Advancing the Careers of Fluid Power and Motion Control Professionals

Physical Address
1930 E. Marlton Pike A-2
Cherry Hill, NJ 08003
Mailing Address
P.O. Box 1420

Cherry Hill, NJ 08034
Phone: 800-303-8520
Fax:
856-424-9248
E-Mail:
info@ifps.org

Groot WEB Services Disclaimer and Copyright  Privacy Policy © 1995-2005 The Fluid Power Society